Parking lots present unique drainage challenges: large impervious areas, concentrated pollutants, and the need to maintain usability during storm events. This guide covers the engineering principles for effective parking lot drainage design.

Design Objectives

A well-designed parking lot drainage system must:

  1. Collect water efficiently - Prevent ponding that impedes use
  2. Convey safely - Route water without causing erosion or flooding
  3. Meet regulations - Comply with quantity and quality requirements
  4. Minimize maintenance - Resist clogging and damage
  5. Protect receiving waters - Address pollutant loads

Surface Grading

Standard Slopes

Proper grading prevents ponding while avoiding excessive velocities:

SurfaceMinimum SlopeMaximum SlopeTarget
Parking areas1.0%5.0%2.0%
Drive lanes0.5%8.0%2.0%
Pedestrian areas1.0%5.0%2.0%
Gutter flow lines0.5%8.0%1.0%

Grading Patterns

Cross-slope to center drain:

  • Parking slopes toward center drive aisle
  • Inlets located in drive aisles
  • Minimizes ponding in parking stalls

Crown and sheet flow:

  • High point along center of lot
  • Water flows toward edges
  • Inlets at perimeter

Single direction:

  • Entire lot slopes one direction
  • Simple grading
  • May concentrate flows

Avoiding Common Grading Problems

Problem: Ponding at low points Solution: Verify inlet locations match grading, ensure positive drainage

Problem: Water flowing across pedestrian paths Solution: Intercept with trench drain or regrade

Problem: Excessive velocity in drive aisles Solution: Add intermediate inlets, reduce slope, or use texturing

Inlet Design and Placement

Types of Inlets

Grate inlets:

  • Metal grate over catch basin
  • Good for areas with vehicle traffic
  • Must be bicycle and ADA safe
  • Capacity depends on grate type and length

Curb inlets:

  • Opening in curb face
  • Common in parking lots with curbing
  • Less prone to clogging
  • Requires curb and gutter

Combination inlets:

  • Both grate and curb opening
  • Higher capacity
  • Good for critical locations

Trench drains:

  • Linear inlet
  • Intercepts sheet flow
  • Common at building entries
  • Requires regular maintenance

Inlet Spacing

Inlet spacing depends on:

  • Contributing area
  • Slope and cross-slope
  • Allowable spread (water width in gutter)
  • Inlet capacity

Rule of Thumb Starting Points:

ConditionTypical Inlet Spacing
Drive aisles (2% slope)200-400 feet
Low areasInlet at each low point
Building entriesTrench drain at entry
Pedestrian crossingsIntercept flow before crossing

Inlet Capacity Calculation

For grate inlets in sag (low point) conditions:

Where:

  • Q = Capacity (cfs)
  • Cw = Weir coefficient (typically 3.0)
  • L = Grate perimeter (feet)
  • d = Depth at grate (feet)

For grate inlets on grade:

Calculate inlet capacity →

Sump Condition Requirements

When an inlet is in a sump (low point with no overflow):

  • Design for 50% clogging minimum
  • Provide secondary overflow path
  • Consider dual inlets
  • Size for critical storm (often 100-year check)

Storm Sewer Design

Pipe Sizing

Use Manning’s equation for gravity pipe flow:

Design Criteria:

ParameterTypical Standard
Minimum pipe size12” (some areas 15”)
Minimum velocity2.5 fps (self-cleaning)
Maximum velocity15 fps (erosion)
Minimum cover2-3 feet
Minimum slope0.5% (size dependent)

Pipe Layout

Best Practices:

  • Route along drive aisles where possible
  • Minimize conflicts with utilities
  • Provide manholes at direction changes
  • Locate clean-outs for maintenance access

Manhole Spacing:

  • Maximum 400-500 feet between structures
  • At all pipe junctions
  • At direction changes > 45°
  • At size changes

System Layout Example

For a 2-acre parking lot:

  1. Identify low points and flow paths
  2. Locate inlets to intercept flow
  3. Connect inlets with pipe, sloping to outlet
  4. Size pipe for cumulative flow at each point
  5. Verify capacity at outlet

Calculate pipe capacity →

Hydrologic Calculations

Rational Method Application

For parking lot design, the Rational Method is typically appropriate:

Typical Runoff Coefficients:

SurfaceC Value
Asphalt pavement0.90-0.95
Concrete pavement0.90-0.95
Gravel parking0.50-0.70
Landscape islands0.20-0.35
Composite (typical)0.85-0.90

Time of Concentration

For parking lots, Tc is often short:

  • Sheet flow across lot: 5-10 minutes
  • Total Tc: Often 10-15 minutes

Short Tc means high rainfall intensity, which drives pipe sizing.

Example Calculation

Given:

  • Parking area: 3 acres
  • Composite C: 0.90
  • Tc: 10 minutes
  • 10-year intensity (from IDF): 5.8 in/hr

Peak Flow:

This is the total outflow the system must handle.

Calculate peak flow →

Stormwater Quality

Pollutant Loads

Parking lots generate significant pollutants:

PollutantSourceConcern
Oil and greaseVehiclesAquatic toxicity
Heavy metalsBrake pads, tiresBioaccumulation
SedimentPavement wear, dirtHabitat degradation
NutrientsLandscape fertilizerEutrophication
TrashLitterAesthetics, wildlife

Best Management Practices (BMPs)

Source Controls:

  • Regular sweeping
  • Spill prevention
  • Good housekeeping
  • Covered dumpsters

Structural BMPs:

  • Oil/water separators
  • Hydrodynamic separators
  • Bioretention/rain gardens
  • Permeable pavement
  • Filter strips

Water Quality Volume

Many jurisdictions require treatment of a “water quality volume”:

Where:

  • WQV = Water quality volume (acre-feet)
  • P = Design rainfall depth (often 1” or 90th percentile)
  • Rv = Runoff coefficient (0.05 + 0.009 × I)
  • I = Impervious percentage
  • A = Area (acres)

Oil/Water Separators

When Required

Oil/water separators are typically required for:

  • Vehicle service areas
  • Gas stations
  • Fleet parking
  • Industrial facilities
  • High-traffic commercial lots (varies by jurisdiction)

Sizing

Separators are sized based on flow rate and required treatment level:

Gravity Separators:

Where:

  • V = Separator volume
  • Q = Design flow
  • t = Retention time (typically 15-30 minutes)

Coalescing Plate Separators:

  • Smaller footprint
  • Higher efficiency
  • More expensive

Maintenance

Critical for separator function:

  • Regular inspection (monthly minimum)
  • Remove accumulated oil
  • Clean out sediment
  • Maintain records for compliance

Detention Requirements

Quantity Control

Most jurisdictions require detention to limit post-development flows:

Common Standards:

  • Control 10-year and 100-year peaks to pre-development
  • Or control to specific release rate
  • May also require volume matching

Detention Options for Parking Lots

Surface detention:

  • Use parking area for temporary storage
  • Design for maximum 6” depth in parking
  • Controlled outlet structure

Underground detention:

  • Below parking surface
  • Pipe systems, chambers, or vaults
  • Higher cost, saves space

Adjacent ponds:

  • Traditional wet or dry pond
  • Often combined with water quality
  • Requires land area

Parking Lot as Detention

Using the parking lot itself for detention storage:

Advantages:

  • No additional land needed
  • Dual use of space
  • Cost effective

Constraints:

  • Maximum 6” depth (ADA, usability)
  • Must drain within 24-72 hours
  • Outlet must prevent blockage
  • Signs may be required

Calculation:

Example: 2-acre lot with 0.4 feet maximum depth:

Special Considerations

ADA Compliance

  • Cross-slopes in accessible routes: 2% maximum
  • Accessible parking areas must drain without puddles
  • Grates must have compliant opening patterns
  • No ponding in accessible paths of travel

Cold Climate Design

  • Consider ice formation at inlets
  • Salt-resistant materials
  • Adequate slopes for snowmelt
  • Snow storage area drainage
  • Consider salt/sand impacts on BMPs

High-Traffic Areas

Drive-through lanes and high-traffic areas:

  • Increase inlet capacity (more clogging)
  • More frequent maintenance
  • Durable grate materials
  • Consider trench drains

Pedestrian Safety

  • Intercept flow before crosswalks
  • Limit gutter spread at crossings
  • ADA-compliant grating
  • Clear sight lines to inlets

Maintenance Considerations

Design for Maintenance

  • Accessible inlet locations
  • Adequate manhole spacing
  • Cleanout provisions
  • Trash racks at outlets
  • Sediment forebays
ElementFrequency
Inlet inspection/cleaningMonthly
Catch basin cleanoutAnnually or as needed
Pipe jettingEvery 3-5 years
Oil separator servicePer permit/manufacturer
SweepingMonthly minimum
BMP maintenancePer design specs

Summary: Design Checklist

  1. Grading

    • Minimum 1% slope on paved areas
    • Positive drainage to all inlets
    • ADA compliance verified
  2. Inlets

    • Located at all low points
    • Properly sized for design flow
    • 50% clogging factor at sump locations
    • Bicycle/ADA safe grates
  3. Storm Sewers

    • Sized for design storm
    • Minimum 12” diameter
    • Adequate slope for self-cleaning
    • Manholes at proper spacing
  4. Hydrology

    • Peak flows calculated
    • Design storm per local standards
    • Downstream impacts considered
  5. Water Quality

    • BMP requirements identified
    • Water quality volume calculated
    • Oil/water separator if required
  6. Detention

    • Release rate requirements met
    • Storage volume verified
    • Outlet sized and protected

References

  1. Federal Highway Administration. (2013). Urban drainage design manual (3rd ed., Hydraulic Engineering Circular No. 22). U.S. Department of Transportation.

  2. American Society of Civil Engineers. (2017). Design and construction of urban stormwater management systems (ASCE Manual of Practice No. 77). ASCE Press.

  3. American Iron and Steel Institute. (2020). Handbook of steel drainage and highway construction products. AISI.

  4. Environmental Protection Agency. (2021). National menu of best management practices for stormwater. EPA.

  5. Americans with Disabilities Act Accessibility Guidelines. (2010). Chapter 4: Accessible routes. U.S. Access Board.

  6. Institute of Transportation Engineers. (2010). Parking generation (4th ed.). ITE.

Ready to Apply What You've Learned?

Use our free professional-grade calculators to design your drainage systems with confidence.

Browse Calculators