Try a Common Scenario
Click to pre-fill the calculator with realistic values.
Calculate flow rate (Q) and velocity (V) for a circular gravity pipe from its diameter, slope and roughness with Manning’s equation. Compare full and partially full flow in US customary or metric units. For a ditch, swale, or noncircular cross-section, use the open channel flow calculator.
Need a diameter for a design flow? Use the storm drain pipe sizing calculator (US). Need a roughness value? Open the Manning's n table by material.
Manning’s equation for circular pipe flow
Manning’s equation is Q = (k/n)AR2/3S1/2, with V = Q/A. For a full circular pipe, A = πD2/4 and P = πD, so R = A/P = D/4. Use k = 1.486 in US customary units or 1.0 in SI. It applies to uniform gravity/free-surface flow, not a pressurized or surcharged pipe.
Sources: FHWA HEC-22, FHWA HDS-4, and EPA SWMM.
For educational purposes only. Not a substitute for professional engineering judgment.
Manning's equation is empirical and assumes uniform, steady flow conditions
Not valid for pressurized (surcharged) pipe flow - use pressure flow equations instead
Accuracy decreases for very smooth pipes (n < 0.010) or very rough pipes (n > 0.035)
Does not account for entrance/exit losses or other minor losses
Partial flow calculations assume free surface (atmospheric pressure at water surface)
Maximum Q/Qfull occurs at approximately y/D = 0.94, not at full flow
Air entrainment effects near the pipe crown are not considered
References formatted in APA 7th Edition style.
- Chow, V. (1959). Open-Channel Hydraulics. New York, NY: McGraw-Hill.textbook
- Federal Highway Administration (2009). Urban Drainage Design Manual (3rd ed.). Washington, DC: U.S. Department of Transportation. https://www.fhwa.dot.gov/engineering/hydraulics/pubs/10009/10009.pdfView Source manual
- United States Army Corps of Engineers (1994). Hydraulic Design of Flood Control Channels. Washington, DC: U.S. Army Corps of Engineers. https://www.publications.usace.army.mil/Portals/76/Publications/EngineerManuals/EM_1110-2-1601.pdfView Source manual
Interactive model
Interactive Manning partial-flow pipe geometry
Adjust diameter, roughness, slope, and y/D to see flow area, wetted perimeter, hydraulic radius, velocity, and discharge change together.
Open full model (opens in a new tab)Gravity pipe flow & full-pipe capacity
Full-bore gravity capacity of a circular pipe in cubic feet per second (cfs), with the full-flow velocity in ft/s underneath, at n = 0.013 (concrete pipe, and conservative for smooth plastic). Use the calculator above for a partly full pipe, another n or metric units.
| Diameter | Qfull at 0.5% slope | Qfull at 1% slope | Qfull at 2% slope |
|---|---|---|---|
| 8 in | 0.85 cfs 2.4 ft/s | 1.21 cfs 3.5 ft/s | 1.71 cfs 4.9 ft/s |
| 10 in | 1.55 cfs 2.8 ft/s | 2.19 cfs 4.0 ft/s | 3.10 cfs 5.7 ft/s |
| 12 in | 2.52 cfs 3.2 ft/s | 3.56 cfs 4.5 ft/s | 5.04 cfs 6.4 ft/s |
| 15 in | 4.57 cfs 3.7 ft/s | 6.46 cfs 5.3 ft/s | 9.14 cfs 7.4 ft/s |
| 18 in | 7.43 cfs 4.2 ft/s | 10.5 cfs 5.9 ft/s | 14.9 cfs 8.4 ft/s |
| 21 in | 11.2 cfs 4.7 ft/s | 15.8 cfs 6.6 ft/s | 22.4 cfs 9.3 ft/s |
| 24 in | 16.0 cfs 5.1 ft/s | 22.6 cfs 7.2 ft/s | 32.0 cfs 10.2 ft/s |
| 27 in | 21.9 cfs 5.5 ft/s | 31.0 cfs 7.8 ft/s | 43.8 cfs 11.0 ft/s |
| 30 in | 29.0 cfs 5.9 ft/s | 41.0 cfs 8.4 ft/s | 58.0 cfs 11.8 ft/s |
| 36 in | 47.2 cfs 6.7 ft/s | 66.7 cfs 9.4 ft/s | 94.3 cfs 13.3 ft/s |
Computed with this calculator’s engine: Q = (1.486/n)AR2/3S1/2, A = πD2/4 and R = D/4. Capacity scales with √S and with 1/n, so a pipe at n = 0.010 carries 30% more than the table shows. Storm drains also need a velocity, cover and hydraulic-grade-line check; to pick a diameter for a known design flow, use the storm drain pipe sizing calculator.
How it works
Manning's equation relates gravity flow in a pipe or channel to its slope, roughness and cross-sectional geometry. This calculator applies it to a circular pipe for two cases: flowing full and flowing partly full.
Discharge and velocity (Manning's equation):
- Q = (k / n) · A · R2/3 · S1/2
- V = (k / n) · R2/3 · S1/2, and Q = V · A
where:
- Q = discharge (cfs or m³/s)
- V = average velocity (ft/s or m/s)
- n = Manning's roughness coefficient (dimensionless)
- A = flow cross-sectional area (ft² or m²)
- P = wetted perimeter (ft or m)
- R = hydraulic radius = A / P (ft or m)
- S = slope of the energy line (ft/ft or m/m)
- k = unit conversion factor = 1.486 for US customary units, 1.0 for SI units (Chow 1959; some US references use 1.49, a difference of under 0.3%)
Full-pipe geometry (diameter D):
- Flow area: A = πD² / 4
- Wetted perimeter: P = πD
- Hydraulic radius: R = A / P = D / 4
Partial-flow geometry uses the central angle θ subtended by the water surface for a flow depth y:
- θ = 2 · cos-1(1 − 2y/D) (radians)
- Flow area: A = (D² / 8)(θ − sinθ)
- Wetted perimeter: P = Dθ / 2
The calculator also reports the Froude number, Fr = V / √(g · Dh), where Dh is the hydraulic depth (A/T). Fr < 1 is subcritical flow, Fr = 1 is critical, and Fr > 1 is supercritical.
Manning's n for common pipe materials
Roughness coefficients for closed conduits, from the same data as the calculator’s material list and the Manning’s n reference page. Use the typical value for design; the min–max range reflects condition and age. Each row names its source table.
| Material | Condition | n (min) | n (typical) | n (max) | Source |
|---|---|---|---|---|---|
| PVC | Smooth interior | 0.009 | 0.010 | 0.011 | HEC-22 (2024) Table 9.1 |
| HDPE | Corrugated exterior, smooth interior | 0.009 | 0.012 | 0.015 | HEC-22 (2024) Table 9.1 |
| HDPE | Corrugated interior | 0.018 | 0.020 | 0.025 | HEC-22 (2024) Table 9.1 |
| Concrete | Precast pipe, good joints | 0.011 | 0.013 | 0.013 | HDS-4 (2008) Table B.3 |
| Concrete | Poor joints, deteriorated walls | 0.014 | 0.017 | 0.018 | HDS-4 (2008) Table B.3 note |
| Vitrified Clay | Sewer pipe | 0.011 | 0.014 | 0.017 | Chow (1959) Table 5-6 |
| Ductile Iron | Cement-mortar lined | 0.011 | 0.013 | 0.015 | Chow (1959) Table 5-6 |
| Spiral Rib Metal | Smooth walls | 0.012 | 0.013 | 0.013 | HDS-4 (2008) Table B.3 |
| Corrugated Metal | 2-2/3 × 1/2 in corrugations, unpaved | 0.022 | 0.024 | 0.027 | HDS-4 (2008) Table B.3 |
| Corrugated Metal | 3 × 1 in corrugations, unpaved | 0.027 | 0.028 | 0.028 | HDS-4 (2008) Table B.3 |
| Corrugated Metal | 6 × 2 in corrugations (structural plate) | 0.033 | 0.035 | 0.035 | HDS-4 (2008) Table B.3 |
HEC-22’s plastic-pipe values are laboratory values; many agencies design PVC and HDPE at 0.012–0.013 to allow for joints and aging. A fuller table including box culverts and paved-invert CMP is available on the Manning's n reference page.
Worked example
A 24-inch (2 ft) precast concrete pipe (n = 0.013) laid at a 1% slope (S = 0.01), flowing full:
- Flow area A = π × 2² / 4 = 3.14 ft²
- Hydraulic radius R = D / 4 = 2 / 4 = 0.50 ft
- Velocity V = (1.486 / 0.013) × 0.502/3 × 0.011/2 ≈ 7.20 ft/s
- Discharge Q = V × A = 7.20 × 3.14 ≈ 22.6 cfs
The 7.20 ft/s velocity is above the 3 ft/s full-flow minimum HEC-22 sets for storm drains and below the ~15 ft/s abrasion threshold, so the slope suits this pipe.
Self-cleansing vs erosion velocity
Too slow (< 2–3 ft/s)
FHWA HEC-22 asks storm drains for at least 3 ft/s (0.9 m/s) flowing full; 2 ft/s (0.6 m/s) is the common sanitary-sewer minimum. Slower than that, sediment and solids settle out and gradually clog the pipe. Fix it by increasing the slope or reducing the diameter so the same flow runs deeper and faster.
Too fast (> ~15 ft/s)
Above about 15 ft/s (4.5 m/s) high velocity can abrade the pipe wall and damage joints. Flatten the slope, increase the diameter, or add energy dissipation at the outlet.
Remember that peak discharge in a circular pipe occurs near y/D = 0.94, and peak velocity near y/D = 0.81 — not at full bore. Storm drains are normally sized to run at or just below full gravity capacity and then checked against the hydraulic grade line; sanitary sewers are often limited to a depth ratio of about 0.5–0.75 by local standards.
Frequently asked questions
What is Manning's equation for pipe flow?
Manning's equation is an empirical formula for uniform, steady open-channel flow. For a circular pipe it is written V = (k/n) R^(2/3) S^(1/2) for velocity and Q = (k/n) A R^(2/3) S^(1/2) for discharge, where n is the roughness coefficient, R is the hydraulic radius (A/P), S is the slope, and A is the flow area. The factor k is 1.486 in US customary units and 1.0 in SI units. It applies to gravity (free-surface) flow, not pressurized flow.
How much flow can a 12-inch pipe carry?
Flowing full with n = 0.013 (concrete pipe, or a conservative value for smooth plastic), a 12-inch gravity pipe carries about 2.52 cfs (1,130 gpm) at 0.5%, 3.56 cfs (1,600 gpm) at 1% and 5.04 cfs (2,260 gpm) at 2% slope. Capacity grows with the square root of slope, so doubling the slope adds about 41%. These are full-bore gravity capacities from Manning’s equation; check the design flow depth, velocity and hydraulic grade line before choosing a size.
Does a pipe carry the most flow when it is exactly full?
No. Because the wetted perimeter increases faster than the flow area near the crown, the maximum discharge in a circular pipe actually occurs at a depth of about y/D = 0.94 (roughly 94% full), where capacity is a few percent higher than at full bore. Maximum velocity occurs at about y/D = 0.81. Storm drains are normally sized to carry the design flow at or just below full-pipe gravity capacity (FHWA HEC-22, 4th ed., §9.1.2) and then checked against the hydraulic grade line. Sanitary sewers are often limited to a depth ratio of about 0.5-0.75 by local standards.
What is a good flow velocity for a drainage pipe?
FHWA HEC-22 recommends a full-flow velocity of at least 3 ft/s (0.9 m/s) for storm drains so sediment keeps moving (self-cleansing); 2 ft/s (0.6 m/s) is the common minimum for sanitary sewers, and some agencies accept 2-2.5 ft/s for storm drains. On the high end, velocities above roughly 15 ft/s (4.5 m/s) raise the risk of abrasion and joint damage, so energy dissipation or a flatter slope may be needed.
Which Manning's n should I use for my pipe material?
Match n to the pipe material and condition. HEC-22 (2024) Table 9.1 lists smooth-wall PVC at n = 0.009–0.011 and smooth-interior (dual-wall) HDPE at 0.009–0.015. Those are laboratory values, and many agencies design plastic pipe at 0.012–0.013 to allow for joints and aging. HDS-4 (2008) Table B.3 gives precast concrete pipe with good joints 0.011–0.013, and 0.013 is the usual design value. Vitrified clay sewer pipe is 0.011–0.017, and corrugated metal pipe runs from 0.022–0.027 for 2-2/3 × 1/2 in corrugations up to 0.033–0.035 for structural plate. The table on this page lists each value with its source. When in doubt, use the rougher value for a conservative capacity.
Can I use this calculator for pressurized (surcharged) pipes?
No. Manning's equation assumes free-surface gravity flow at atmospheric pressure. Once a pipe surcharges and flows under pressure, you need pressure-flow (e.g., Hazen-Williams or Darcy-Weisbach with the energy grade line) instead. If the calculator shows the pipe flowing more than about 80% full, treat the result as a capacity warning rather than a steady design point.
What This Solves
Calculates the flow rate and velocity in a circular pipe using Manning's equation for gravity-driven (non-pressurized) conditions.
Best Used When
- You are sizing a storm sewer or drainage pipe for a known design flow
- You need to check whether an existing pipe has enough capacity
- You want to evaluate partial-flow depth and velocity in a circular pipe
Do NOT Use When
- The pipe is flowing under pressure (surcharged condition) — Use Culvert Outlet Control Calculator
- You are analyzing an open channel rather than a closed pipe — Use Manning's Channel Calculator
- You need to find the depth at which uniform flow occurs for a given discharge — Use Normal Depth Calculator
Key Assumptions
- Flow is uniform and steady (not rapidly changing)
- The pipe has a constant slope and cross-section along its length
- Flow is gravity-driven with a free water surface (not pressurized)
- Roughness is uniform throughout the pipe
- Fully developed turbulent flow conditions exist
Input Quality Notes
The Manning's n value has the largest effect on results. Use published values for the specific pipe material and condition (new vs. aged). Slope should be the actual energy grade line slope, not just the pipe invert slope, though they are equal for uniform flow.
Was this calculator helpful?
Last verified: February 2026